流量計設置零點
Flowmeter Setting Zero Point
注:(流量計安裝後必須先進置零操作)
Note: (Flowmeter must be set to zero first after installation)
由于電容式力傳感器及阻流件有自重,在流量計安🏃🏻♀️裝💔時不在水平方位
狀況下,需要重新設置流量計零點。操作程序爲:(也💁🏼♀️可在👱🏼♂️管道内👩🏼❤️👨🏾無介質流動時直接置零,高溫型及低👩🏽🐰👩🏿溫型流量計必須使管道内溫度達到工作溫度後👩🏿❤️💋👨🏽置零)
Because of the self-weight of capacitive force transducer and blocker, it is not in horizontal position when flowmeter is installed.
In this case, it is necessary to reset the zero of the flowmeter. Operating procedures are as follows: (also can be placed directly in the pipeline without medium flow, high-temperature and low-temperature flowmeters must make the temperature in the pipeline reach zero after working temperature)
a、關閉流量計下遊的閥門;
A. Close the valve downstream of the flowmeter;
b、緩慢打開流量計上遊閥門,使流量計充滿介質;
B. Slowly open the upstream valve of the flowmeter to fill the flowmeter with medium.
c、緩慢打開流量計下遊閥門,使流量計運行10分鍾左右;
C. Slowly open the downstream valve of the flowmeter to make the flowmeter run for about 10 minutes.
d、關閉流量計上、下遊閥門,并确定管道内流量爲零;
D. Close the upstream and downstream valves of the flowmeter and determine that the flow in the pipeline is zero.
e、用手指按在“<”位置不小于3S:
E. Put your finger at position'<'not less than 3S:
|
次序 |
操作方式 |
功能說明 |
|
1 |
按“<”鍵3S |
将顯示之前零點E1值 |
|
2 |
再次“<”鍵3S |
保存當前零點E1值 |
|
3 |
按“SET”鍵 |
退出置零點狀态 |
|
order |
Operation mode |
Function description |
|
1 |
Press'<'key 3S |
The previous zero E1 value will be displayed |
|
2 |
Again, "<" key 3S |
Save the current zero E1 value |
|
3 |
Press the SET key |
Exit Zero State |
質量流量計直接測量通過流量計的介質的質量🤶🏾流量,還可測量介質的密度及間接測量介質的溫度。由于變送器是以單片機爲核心的智能儀表,因此可根據上述三個基本量而導出多種參數供用😘戶使用。 質量流量計組态靈活🧛🏽,功能強大,性能價格比高,是新一🧎🏻♀️➡️代流量儀表。
查看産品
智能流量計以其特有的抗幹擾、抗雜質性能,除能替代常規😁流量所能測量的流量計量問題,尤其在高粘度、髒污介質、易凝易🔞堵、高溫、低溫、強腐蝕等流量計量困難的工況中具有很好的适應性。 ◆ 管徑範圍寬:Φ15~Φ3000至更大; ◆ 溫度範🧑🏻❤️🧑🏼圍廣:-20 ~ 500℃; ◆ 适用多種介質:氣體、蒸汽😍; ◆ 适用于低流速介質,其可💌測量最低流速爲0.08m/s。
查看産品
電磁流量計是20世紀50~60年代随着電子技術的發展而迅🧑🏽🎄速發展起來的新型流量測量儀表。 電磁流量計是應用電磁感應原理, 根據導電流體通過外加磁場時感生的電動勢來測量導✍🏻電流體流量的一種儀器。